CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體
型號(hào):CIRS008M
類(lèi)別:質(zhì)控模體品牌:美國(guó)CIRS
pdf資料:CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體.pdf采購(gòu)熱線:0755-28896837  136-3292-5349 
 CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體詳細(xì)介紹:CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體
圖像采集,治療計(jì)劃,劑量輸送
圖像采集,治療計(jì)劃,劑量輸送
CIRSMRI-LINACDynamicPhantom專(zhuān)為端到端調(diào)試,混合MRI-LINAC放射治療系統(tǒng)的機(jī)器QA以及門(mén)控和適應(yīng)性治療計(jì)劃的驗(yàn)證而設(shè)計(jì)。
CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體型提供了評(píng)估MRI圖像質(zhì)量的手段,并且可以測(cè)試腫瘤定位和動(dòng)作捕捉設(shè)備?;糜翱捎糜讷@取移動(dòng)或靜態(tài)目標(biāo)圖像進(jìn)行門(mén)控或適應(yīng)性治療實(shí)施的治療計(jì)劃和驗(yàn)證。
CIRS008MMRI動(dòng)態(tài)模體,CIRS
008M模體帶有目標(biāo)和延伸的剛性軸連接的模體,移動(dòng)桿對(duì)于1.5T磁體是MRI安全的。電機(jī)和運(yùn)動(dòng)控制器電子元件位于離磁鐵安全距離處,以確保MRI圖
像質(zhì)量。MRI-LINACDynamicPhantom利用CIRS運(yùn)動(dòng)控制軟件提供精確,可重復(fù)的3D目標(biāo)運(yùn)動(dòng)。
幻影體在大小和形狀上逼近平均人體。它由帶有圓柱形通孔的塑料外殼組成,以容納具有模擬目標(biāo)的移動(dòng)桿。外殼內(nèi)充滿專(zhuān)有的MRI信號(hào)生成凝膠,可以快速輕松地進(jìn)行幻像設(shè)置,而不會(huì)產(chǎn)生液體運(yùn)動(dòng)偽影?;糜败?chē)身懸掛在非磁軌上,可以進(jìn)行線圈定位和虛擬注冊(cè)到沙發(fā)上。
CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體含有MRI質(zhì)量保證目標(biāo),與ACR認(rèn)證計(jì)劃的建議相符:
MRI圖像空間失真
MRI場(chǎng)均勻性
激光到ISO中心重合
帶有模擬目標(biāo)的活動(dòng)插件是一個(gè)密封的圓柱形桿,其填充了與幻像體相同的MRI信號(hào)生成專(zhuān)用凝膠。嵌入式MRI/
CT靶由MRI凝膠制成,可提供與背景相對(duì)的對(duì)比度。該目標(biāo)可以接收離子室或其他MRI兼容劑量計(jì)用于治療劑量驗(yàn)證。在MRI殼體的外側(cè)上為MRI/
CT目標(biāo)和MRI失真柵格加工出激光標(biāo)記。為了促進(jìn)MRI/
CT圖像融合,存在與外部激光標(biāo)記對(duì)準(zhǔn)的中心基準(zhǔn)點(diǎn),并且在關(guān)于3D空間畸變網(wǎng)格的已知位置。
CIRS008MMRI動(dòng)態(tài)模體,CIRS008M模體特征:
MRI-CT-LINAC兼容
3D目標(biāo)運(yùn)動(dòng)
門(mén)控和自適應(yīng)RT計(jì)劃驗(yàn)證
端到端調(diào)試
MRIQA
ImageAcquisition,TreatmentPlanning,DoseDelivery
TheCIRSMRI-LINACDynamicPhantomisdesignedforend-to-end
commissioning,machineQAforhybridMRI-LINACRadiationTherapy
systems,andverificationofgatedandadaptivetreatmentplans.
TheModel008MprovidesameanstoassessMRIimagequality,andtotest
tumorlocalizationandmotion-capturingdevices.Thephantomcanbe
usedtoacquiremovingorstatictargetimagesfortreatmentplanning
andverificationofgatedoradaptivetreatmentdelivery.
Thephantombody,movingrodwithtargetandextendedrigidshaft
connectionareMRI-safewith1.5Tmagnets.Motorsandmotioncontroller
electronicsarelocatedatasafedistancefromthemagnettoensureMRI
imagequality.TheMRI-LINACDynamicPhantomutilizesCIRSMotion
ControlSoftwaretoprovideprecise,repeatable3Dtargetmotion.
Thephantombodyapproximatesanaveragehumanbodyinsizeandshape.
Itiscomprisedofaplasticshellwithacylindricalthruholeto
accommodateamovingrodwithsimulatedtarget.Theshellisfilledwith
proprietaryMRIsignal-generatinggelthatallowsforquickandeasy
phantomset-upwithoutliquidmotionartifacts.Thephantombodyis
suspendedonnon-magneticrailsthatallowforcoilpositioningand
phantomregistrationtothecouch.
Model008McontainsMRIQAtargetsthatarecompatiblewithACRaccreditationprogramrecommendationsfor:
MRIimagespatialdistortion
MRIfieldhomogeneity
LasertoISOcentercoincidence
Themovinginsertwithsimulatedtargetisasealed,cylindricalrod
filledwiththesameMRIsignal-generatingproprietarygelasthe
phantombody.TheembeddedMRI/CTtargetismadeofMRIgelthat
providescontrastwithrespecttothebackground.Thistargetcan
receiveanionchamberorotherMRI-compatibledosimetersfortreatment
doseverification.TherearelasermarksmachinedontheoutsideofMRI
shellbodyforboththeMRI/CTtargetandMRIDistortionGrid.To
facilitateMRI/CTImagefusion,thereisacentralfiducialalignedwith
theexteriorlasermarks,andinaknownpositionwithrespectto3D
spatialdistortiongrid.
Features:
MRI-CT-LINACCompatible
3Dtargetmotion
GatedandadaptiveRTplanverification
End-to-endcommissioning
MRIQA
SAG: